Karel Kolacek1, Vladislv Bohacek1, Jiri Schmidt1, Pavel Sunka1, Milan Ripa1, Josef Kravarik2
1Institute of Plasma Physics, Academy of Sciences of the Czech Republic, 3 Za Slovankou Str., P.O. Box 17, 182 21 Prague 8, Czech Republic,
2Faculty of Electrical Engineering, Czech Technical University, 2 Technicka Str., 166 27 Prague 6, Czech Republic
A new driver of the fast capillary discharge has been designed. It consists of the Marx generator and radial Blumline pulse forming line. Such a geometry enables axial access to both capillary ends ("transparent capillary"). This arrangement substantially simplifies the experiments (adjustment, monitoring, applications). The designed apparatus is capable of reaching the discharge current of the order of 120 kA and the discharge current rise time 2.9´1012 A/s, which is sufficient for the investigation of amplification in non-traditional electronic transitions.